
Working principle
The miniature suction pump represents the PC pump
The miniature suction pump represents the PC pump
The working principle of micro suction pump with micro vacuum pump working principle is the same, circular motion of the motor, the mechanical device makes the diaphragm inside the pump to do reciprocating motion, thus the pump cavity of fixed volume air compression, stretching to form a vacuum (negative pressure), the pump inlet and the outside atmospheric pressure difference and under the action of the pressure difference of gas pressure (suction) into the pump chamber and then discharged from the exhaust port. Because of air or smoke exhaust and the atmosphere can form a pressure difference, at the same time as large vacuum pump and vacuum pump oil and lubricating oil, will not pollute the medium, and has the advantages of small size, low noise, maintenance free, can be 24 hours of continuous operation and other advantages, so the micro vacuum pump was used as a power device, widely for gas sampling, gas circulation, vacuum adsorption, filtration, accelerate car vacuum booster and so on occasions, has been widely used in the field of medical, health, scientific research, environmental protection etc..
parameter
Micro air pump, suction, suction – PC series
Temperature resistance: 0 to 100 degrees
Main features: 1. high vacuum, high temperature resistant; pumping end with large load (i.e., great resistance) or even blocked; low power consumption, small volume, long service life;
2, no oil, no pollution medium, maintenance free, 24 hours of continuous operation, allowing medium rich in water vapor, arbitrary installation;
Selection method
First, input compressed air: that is, only use it to inflate and inflate, and the exhaust port of the pump is not needed. This situation is relatively simple, according to the output pressure from large to small in turn optional: whipping dual-purpose vacuum pump. Of course, we should also refer to the flow index and other related technical parameters.
Two, pumping or pumping with micro pump or vacuum exhaust, but sometimes there is liquid water enters the pump cavity; micro pump can require pumping and pumping; mainly with micro pump, but do not want to rely on manual pumping before “diversion”; using a micro pump pumping, but some of the time can not pump water can be pumped, in a “dry” state.
Three. For pumping: micro pumps used for pumping are divided into two categories: gas sampling pumps and micro vacuum pumps.
Four, pumping gas, you need to adjust the vacuum and flow: if the pump itself can adjust the flow and vacuum, and LCD panel shows the vacuum, you need to select the smart vacuum pump. Intelligent vacuum pump, because of its intelligence, automation, the use of very convenient, no longer time-consuming, hard work with valves, control circuit to regulate flow and vacuum.
purpose
Micro vacuum pump and micro suction pump, but can be used for gas sampling, gas circulation, gas sampling analysis, accelerated filtration, vacuum absorption, vacuum pumping, pump and so on, can also be used for civilian use, such as beauty, breast, cupping and so on. It is widely used in scientific research, medical treatment, instrumentation, chemical analysis, biological engineering, automatic control, environmental protection, water treatment and many other fields. In some areas, it has even replaced large vacuum pumps.
Entry label:
science
The miniature suction pump represents the PC pump
The miniature suction pump represents the PC pump
The working principle of micro suction pump with micro vacuum pump working principle is the same, circular motion of the motor, the mechanical device makes the diaphragm inside the pump to do reciprocating motion, thus the pump cavity of fixed volume air compression, stretching to form a vacuum (negative pressure), the pump inlet and the outside atmospheric pressure difference and under the action of the pressure difference of gas pressure (suction) into the pump chamber and then discharged from the exhaust port. Because of air or smoke exhaust and the atmosphere can form a pressure difference, at the same time as large vacuum pump and vacuum pump oil and lubricating oil, will not pollute the medium, and has the advantages of small size, low noise, maintenance free, can be 24 hours of continuous operation and other advantages, so the micro vacuum pump was used as a power device, widely for gas sampling, gas circulation, vacuum adsorption, filtration, accelerate car vacuum booster and so on occasions, has been widely used in the field of medical, health, scientific research, environmental protection etc..
parameter
Micro air pump, suction, suction – PC series
Temperature resistance: 0 to 100 degrees
Main features: 1. high vacuum, high temperature resistant; pumping end with large load (i.e., great resistance) or even blocked; low power consumption, small volume, long service life;
2, no oil, no pollution medium, maintenance free, 24 hours of continuous operation, allowing medium rich in water vapor, arbitrary installation;
Selection method
First, input compressed air: that is, only use it to inflate and inflate, and the exhaust port of the pump is not needed. This situation is relatively simple, according to the output pressure from large to small in turn optional: whipping dual-purpose vacuum pump. Of course, we should also refer to the flow index and other related technical parameters.
Two, pumping or pumping with micro pump or vacuum exhaust, but sometimes there is liquid water enters the pump cavity; micro pump can require pumping and pumping; mainly with micro pump, but do not want to rely on manual pumping before “diversion”; using a micro pump pumping, but some of the time can not pump water can be pumped, in a “dry” state.
Three. For pumping: micro pumps used for pumping are divided into two categories: gas sampling pumps and micro vacuum pumps.
Four, pumping gas, you need to adjust the vacuum and flow: if the pump itself can adjust the flow and vacuum, and LCD panel shows the vacuum, you need to select the smart vacuum pump. Intelligent vacuum pump, because of its intelligence, automation, the use of very convenient, no longer time-consuming, hard work with valves, control circuit to regulate flow and vacuum.
purpose
Micro vacuum pump and micro suction pump, but can be used for gas sampling, gas circulation, gas sampling analysis, accelerated filtration, vacuum absorption, vacuum pumping, pump and so on, can also be used for civilian use, such as beauty, breast, cupping and so on. It is widely used in scientific research, medical treatment, instrumentation, chemical analysis, biological engineering, automatic control, environmental protection, water treatment and many other fields. In some areas, it has even replaced large vacuum pumps.
Entry label:
science